Risk areas in the sector!
Due to its shape and size, the FIRE DESTROYER unit is designed for installation in industrial electrical cabinets and servers.
-10%
135.56 € 122.00 € Z DDV (100.00 € BREZ DDV)
Standards
- V skladu s standards GA 602-2013, 2013/29/EU, DIN EN 16263-5:2021-7
- Preizkus vzorca in CE certifikat
- Patent for the shchita
- Mednarodno zaščitena blagovna znamka
The splendor
- FIRE DESTROYER AEROSOL DISK zagotavlja aktivno zaščito pred požarom v prostorih, v katerih se nahaja draga tehnologija, ki je je gasilni medij ne sme poškodovati.
- Gasilni medij je neškodljiv za okolje in judi.
- Učinkovit je za požare razreda A / B / C / F.
- Hiro odzivanje: In the first place, the first one can be stored in the same gas tank for 3-5 seconds, so that it can be stored in the first place.
- Specifications:
Dimensions: 130 mm x 130 mm
Prostornina gašenja: 1.5 m³ (150 g), 3 m³ (300 g), 10 m³ (1000 g)
Gas medium: AEROSOL type S
Uporaba
Enostavna namestitev in uporaba: DISK FIRE DESTROYER AEROSOL if you remove the dirt from the dirt, you will need to clean the surface to be able to turn it off. Observe that each cycle should be used for 3-5 seconds, with medium gas if it is too high.
Guarantee
Garancijska doba diska je 4 leta in ne zahteva dodatnega vzdrževanja.
-10%
Of the prijatelji
Technical data
Response time
3-5 seconds.
For extinguishing class fires
A, B, C, F.
Power off volume
1m³ (100g)
1.5 m³ (150 g),
3 m³ (300 g),
10m³ (1000g)
Installation time
about 15 minutes.
Dimensions
130mm x 130mm
Warranty period
4 years and requires no additional maintenance
The most common causes of ignition.
- Old and worn fuses
- Non-professional connection
- Power grid overload
- Poor quality of material
- Overheating
- Pollution
- Mechanical damage
- Damage caused by rodents
Installation
DISK FIRE DESTROYER AEROSOL is fixed on a flat surface with four screws and the ignition cord is distributed over the entire area of the potential fire source. Upon contact with fire, the mechanism is activated within 3-5 seconds and the extinguishing agent is dispersed throughout the room. FIRE DESTROYER AEROSOL DISK provides active fire protection in rooms where expensive technological devices are installed that must not be damaged by the extinguishing agent. Due to the dimensions of the product and the capacity of the extinguishing agent, this product is suitable for rooms up to 10 m³. It is suitable for installation in a wide variety of spaces and areas.
Step by step installation instructions:
Package Contents: The box contains 4 screws, a 10 meter long ignition cable and an automatic FIRE DESTROYER disc with four mounting holes.
1. Clean the selected installation location.
2. Place the spray disc in the chosen installation location.
3. Secure the unit with all four screws.
4. Place the ignition wire behind the disc, where the potential fire source is located.
Done. Make sure all screws are tightened.
easy to use
tested and certified
respectful of the environment and people
compact and lightweight
Electrical cabinets and servers
- Why does electricity cause so many fires? Heating wires and electrical components can become loose and deteriorate the contact. Fires can be caused by power lines, worn components in the electrical cabinet, as well as by the lack of maintenance of household appliances, poorly maintained connections and overloaded electrical installations. Improperly used extension cords are themselves a cause of fire. Worn cables, loose wires and fuses in electrical wiring, as well as other unmaintained components, over time begin to overheat and, due to a short circuit, cause sparks and, as a result, a fire. At that time, flammable materials and components in the vicinity of the event will also be affected and a fire will develop.
Fires on boats and barges
- 26% Fires are caused by sources external to the vessel. Typically a fire starts on a nearby vessel and then engulfs ours. External sources of fire may also include a fire in the garage or house where the vessel is stored. Protect yourself from potential claims for compensation in the event of a fire on your vessel.
- 20% of fires are caused by poor electrical installation of a boat engine. The cause is usually poor contacts of old cables. This happens more often on boats that are over 25 years old, whose contacts are already heavily oxidized. If you have an older boat, we recommend that you inspect all electrical cables and replace worn ones, as well as clean all contacts regularly. Remember that due to high temperatures in the engine compartment, salt and humidity in the air, the insulation of the cables will lose its insulating properties sooner than expected and will have to be completely replaced.
- 15% of fires are caused by problems with the DC electrical wiring of the boat (12V, 24V). The danger is usually caused by batteries on the boat, poor insulation of the cables, bad contacts on the connectors, reversed polarity and incorrect cable connections. Whenever you need to replace certain equipment on your boat, when disconnecting the connectors, first mark the cables as positive and negative and, after reassembly, check that they are connected correctly.
- 12% of fires start in the 220V AC electrical wiring of a boat. In most cases the problem is due to poor contact in the cable that connects the boat to the electrical system on the dock or in the harbor. Before connecting the boat to an external power source, check that the power source is in good condition and that the cable is not damaged. Replace it at least every 10 years.
- The 9% fire is caused by an overheated engine. If the cooling water supply to the engine is cut off and not turned off in time, the engine is very likely to overheat. The flow of cooling water to the engine may be blocked by a blocked intake opening (in the case of a Z-drive, a PVC bag may be collected in the sea to block the flow of water. If the engine temperature rises, stop the boat and inspect the leg to see if the bag is stuck. When the bag is removed, the engine will run at idle speed to cool slowly.). The second cause is usually a worn or damaged impeller, which prevents the engine from receiving enough water for cooling. It is recommended to replace the impeller every 2 years.
- 8% of fires are caused by batteries in outboard motor boats. In older motors, over 10 years old, the cause of the fire is the voltage regulator. If you do not replace it sooner, make sure to do it at the latest when the motor is 15 years old.
- Fire cause data are statistics obtained from insurance companies and their claims for damages in the event of a fire on board a ship. An extremely effective protection against fires is an automatic fire extinguisher, which is activated upon contact with the fire and puts it out before it spreads.
-10%
